Oferta


Automatyka przemysłowa

Filtruj


Producent

Cena promocyjna

SGB2K2AC5


Waga produktu: 680g

Minimalna ilość w zamówieniu: 1

Ilość produktów w opakowaniu jednostkowym: 1

Opis produktu


Kluczykowy przełącznik blokady drzwi SG-B2

Item Specifications
Product Number SG-B2-K2AC-5
Part Number SG-B2-K2AC-5
Contact arrangement
Cable length 5m
16.404 ft
Key removal position A
(removable in all positions)
Applicable standards EN 60947-5-1, GS-ET-19
Applicable standards : Standards for use IEC 60204-1 / EN 60204-1, ISO 14119, EN ISO 14119, IEC 60947-5-1, UL 508, CSA C22.2 No.14
Applicable regulations CE Marking [Machinery Directive (2006/42/EC), RoHS Directive], UKCA Marking [Supply of Machinery (Safety) Regulations (2008 No.1597), RoHS Regulations]
Operating condition : Ambient temperature -25 to +70 ℃ -13 to +158 ℉ (No dew condensation or icing allowed)
Storage : -40 to +80 ℃ -40 to +176 ℉
Operating condition : Ambient humidity 45 to 85 % RH
Operating condition : Pollution degree 3 (Inside 2)
Operating condition : Altitude 2,000 m 6,561.68 ft max.
Impulse withstand voltage (Uimp) 2.5 kV
Rated insulation voltage (Ui) 250 V
(Note): Ratings approved by UL, c-UL : 125 V
Thermal current (Ith) ・2.5 A
・Ambient temperature :
-25 to +60 ℃ -13 to +140 ℉ : 2.5 A max.
+60 to +65 ℃ +140 to +149 ℉ : 1.5 A max.
+65 to +70 ℃ +149 to +158 ℉ : 1.0 A max.
Rated operational voltage (Ue) / Rated operational current (Ie)
  Ue
  30V 125V 250V
Ie AC Resistive load (AC-12) - 2.5A 1.5A
Inductive load (AC-15) - 1.5A 0.75A
DC Resistive load (DC-12) 2.5A 1.1A 0.55A
Inductive load (DC-13) 2.3A 0.55A 0.27A
Operating frequency 900 operations/hour
Actuator operating speed 0.05 to 1.0 m/sec.
B10D 2,000,000
(ISO 13849-1 Annex C Table C.1)
Mechanical durability 1,000,000 operations min. (GS-ET-19)
Rear unlocking button : 3,000 operations min. (Type SG-B2-□-L5)
Electrical durability 100,000 operations min. (AC-12, 250 V 1 A)
1,000,000 operations min. (AC/DC 24 V 100 mA)
(900 operations/hour)
Electric shock protection class Class II (IEC 61140)(Note), 回(double-insulated)
(Note): Basic insulation of 2.5 kV impulse withstand voltage is ensured between different contact circuits.
When both SELV (safety extra low voltage) or PELV (protective extra low voltage) circuits and other circuits (such as 230 V AC circuits) are used for the solenoid power and contact circuits at the same time, the SELV or PELV requirements are not met any more.
Interlock force 1,400 N min. (GS-ET-19)(Note)
(500 N min. : SG-K24 actuator)
(Note): The actuator locking strength is rated at 1,400 N of static load. Do not apply a load higher than the rated value. When a higher load is expected to work on the actuator, provide an additional system consisting of another safety switch without lock (such as the SG-A1 safety switch) or a sensor to detect door opening and stop the machine.
Direct opening travel 11 mm 0.433 in min. (actuator : SG-K21)
12 mm 0.472 in min. (for other actuators)
Direct opening force 80 N min.
Contact resistance 700 mΩ max. (initial value, 5 m 16.404 ft cable)
Protection IP 65 (IEC 60529)
Shock resistance Malfunction : 100 m/s2, Destruction : 1,000 m/s2
Vibration resistance Malfunction : 10 to 55 Hz, half amplitude 0.35 mm 0.014 in
Destruction : 30 Hz, half amplitude 1.5 mm 0.059 in
Conditional short-circuit current 50 A (250 V)
Short-circuit protective device Use 250 V / 10 A fast acting type fuse
Material Enclosure : PA66
Cable UL style 2464, No.22 AWG 12-core
Key : Operating specifications 2 positions
Key : Mechanical durability 100,000 operations min.
Key : Key operating durability 10,000 operations min.
Key : Key tensile strength 1.0 N・m min.
Key : Direct opening force 0.6 N・m min.
Key : Direct opening degree 60°min.
Weight Approx. 680 g

Mimo dołożenia wszelkich starań nie gwarantujemy, że publikowane dane techniczne oraz zdjęcia nie zawierają braków lub błędów. Ponieważ ewentualne błędy nie mogą być podstawą do roszczeń, w przypadku wątpliwości prosimy przed zakupem o kontakt z handlowcem.