Item Specifications
Product Number SG-B1-SA-G1
Part Number SG-B1-SA-G1
Main contacts 1NC + 1NC
Door monitor contacts 2NC
Lock monitor contacts 1NC
Cable length 1m 3.281 ft
Applicable standards EN 60947-5-1, GS-ET-19
Applicable standards : Standards for use IEC 60204-1 / EN 60204-1, ISO 14119, EN ISO 14119, IEC 60947-5-1, UL 508, CSA C22.2 No.14
Applicable regulations CE Marking [Machinery Directive (2006/42/EC), RoHS Directive], UKCA Marking [Supply of Machinery (Safety) Regulations (2008 No.1597), RoHS Regulations]
Operating condition : Ambient temperature -25 to +50 ℃ -13 to +122 ℉ (No dew condensation or icing allowed)
Storage : -40 to +80 ℃ -40 to +176 ℉
Operating condition : Ambient humidity 45 to 85 % RH
Operating condition : Pollution degree 3 (Inside 2)
Operating condition : Altitude 2,000 m 6,561.68 ft max.
Rated insulation voltage (Ui) 300 V (Door monitor circuit)
150 V (Main, Lock monitor circuit)
30 V (Between ground and LED, solenoid circuit)
Impulse withstand voltage (Uimp) 2.5 kV (Door monitor circuit)
1.5 kV (Main, Lock monitor circuit)
0.5 kV (Between ground and LED, solenoid circuit)
Thermal current (Ith) ・Ambient temperature : -25 to +35 ℃ -13 to +95 ℉
2.5 A (up to 2 circuits)
1.0 A (3 or more circuits)
・Ambient temperature : 35 to +50 ℃ 95 to +122 ℉
1.0 A (1 circuit)
0.5 A (2 or more circuits)
Rated operational voltage (Ue) / Rated operational current (Ie)
  Ue
  30V 125V 250V
Ie Main circuit, look monitor circuit AC Resistive load (AC-12) - 2A -
Inductive load (AC-15) - 1A -
DC Resistive load (DC-12) 2A 0.4A -
Inductive load (DC-13) 1A 0.22A -
Door monitor circuit AC Resistive load (AC-12) - 2.5A 1.5A
Inductive load (AC-15) - 1.5A 0.75A
DC Resistive load (DC-12) 2.5A 1.1A 0.55A
Inductive load (DC-13) 2.3A 0.55A 0.27A
Electric shock protection class Class II (IEC 61140)(Note), 回(double insulated)
(Note): Basic insulation of 2.5 kV, 1.5 kV impulse withstand voltage is ensured between different contact circuits and between contact circuits and LED or solenoid in the enclosure. When both SELV (safety extra low voltage) or PELV (protective extra low voltage) circuits and other circuits (such as 230 V AC circuits) are used for the solenoid power and contact circuits at the same time, the SELV or PELV requirements are not met any more.
Operating frequency 900 operations/hour
Actuator operating speed 0.05 to 1.0 m/sec.
B10D 2,000,000
(ISO 13849-1 Annex C Table C.1)
Mechanical durability 1,000,000 operations min. (GS-ET-19)
Electrical durability 100,000 operations min.
(900 operations/hour,
AC-12 125 V 2A, DC-12 125 V 0.4 A)
1,000,000 operations min.
(900 operations/hour,
24 V AC/DC 0.1 A resistive load)
Interlock force 500 N min. (GS-ET-19)
(Note): The actuator locking strength is rated at 500 N of static load. Do not apply a load higher than the rated value.
Do not apply a load higher than the rated value.
When a higher load is expected to work on the actuator, provide an additional system consisting of another safety switch without lock (such as the SG-A1 safety switch) or a sensor to detect door opening and stop the machine.
Direct opening travel 8 mm 0.315 in min.
Direct opening force 60 N min.
Contact resistance 300 mΩ max. (initial value, 1 m 3.281 ft cable)
700 mΩ max. (initial value, 5 m 16.404 ft cable)
Protection IP 67 (IEC 60529)
Shock resistance Malfunction : 100 m/s2, Destruction : 1,000 m/s2
Vibration resistance Malfunction : 10 to 55 Hz, half amplitude 0.35 mm 0.014 in
Destruction : 30 Hz, half amplitude 1.5 mm 0.059 in
Short-circuit protective device Use 250 V / 10 A fast acting type fuse
Material Enclosure : PA66
Cable UL style 2464, No.22 AWG 12-core
Solenoid / Indicator : Rated operating voltage DC 24 V 100% duty cycle
Solenoid / Indicator : Rated current 110 mA (solenoid 100 mA, LED 10 mA : initial value)
Solenoid / Indicator : Turn on voltage Rated voltage × 85 % max. (at 20 ℃ 68 ℉)
Solenoid / Indicator : Turn off voltage Rated voltage × 10 % min. (at 20 ℃ 68 ℉)
Solenoid / Indicator : Indicator Green LED
Weight Approx. 220 g