HLG112AC5


Typ: Czujniki pomiarowe

Symbol: HL-G112-A-C5

Producent: Panasonic

Waga produktu: 320g

Minimalna ilość w zamówieniu: 1

Ilość produktów w opakowaniu jednostkowym: 1

Opis produktu


Wysokoprecyzyjny laserowy czujnik pomiarowy serii HL-G1

Compact Laser Displacement Sensor, Standard type, 120 mm, cable 5 m

Item Specifications
Product Number HL-G112-A-C5
Part Number HL-G112-A-C5
Regulatory compliance CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations)
Type Standard type
Measurement center distance 120 mm 4.724 in
Measuring range ± 60 mm ± 2.362 in
Resolution 8 μm 0.315 mil
Linearity ± 0.1 % F.S.
Temprerature characteristics ± 0.08 % F.S. / ℃
Light source Red semiconductor laser, Class 2 (IEC / JIS / FDA (Note:This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 50, dated June 24, 2007, issued by CDRH (Center for Devices and Radiological Health) under the FDA (Food and Drug Administration).) , Laser Notice No. 50)
Max. output: 1 mW (Peak emission wavelength: 655 nm 0.026 mil)
Beam diameter 1.0 × 1.5 mm 0.039 x 0.059 in
(Note) This beam diameter is the size at the measurement center distance. These values were defined by using 1/e2 (13.5 %) of the center light intensity. If
there is a slight leakage of light outside the normal spot diameter and if the periphery surrounding the sensing point has a higher reflectivity than the
sensing point itself, then the results may be affected.
Receiving element CMOS image sensor
Supply voltage 24 V DC ± 10 % including ripple 0.5 V (P-P)
Current consumption 100 mA or less
Sampling rate 200 μs, 500 μs, 1 ms, 2 ms
Analog output : Voltage Output range: 0 to +10.5 V (normal), 11 V (alarm)
Output impedance: 100 Ohm
Analog output : Current Output range: 3.2 to 20.8 mA (normal), 21.6 mA (alarm)
Load impedance: 300 Ω or less
Outputs (OUT 1, OUT 2, OUT 3) Judgment output or alarm output (Setting can be selected.)
Selectable NPN transistor open-collector or PNP transistor open-collector
<In case of using NPN output>
-Maximum sink current: 50 mA
-Applied voltage: 3 to 24 V DC (between output and 0 V)
-Residual voltage: 2 V or less (at 50 mA of sink current)
<In case of using PNP output>
-Maximum source current: 50 mA
-Residual voltage: 2.8 V or less (at 50 mA of source current)
Output (OUT 1, OUT 2, OUT 3) : Output operation Opened when the amount of light is insufficient.
Output (OUT 1, OUT 2, OUT 3) : Short circuit protection Incorporated (automatic restoration)
Output polarity setting input NPN open collector output operates when 0 V is connected.
PNP open collector output operates when 24 V DC is connected.
Timing input NPN output operates when 0V is connected and NPN is set. (It depends on the setting.)
PNP output operates when external power + is connected and PNP is set. (It depends on the setting.)
Multi input Zero set, zero set off, reset, memory switching, teaching, saving, and laser control according to the input time.
In case NPN output is selected, Function varies according to the time 0 V is connected NPN.
In case PNP output is selected, Function varies according to the time external power + is connected.
Indicator : Laser emission Green LED (lights up during laser emission)
Indicator : Alarm Orange LED lights up when this product cannot measure because of insuffienct or excessive light intensity.
Indicator : Measurement range Three yellow LED
Digital display Red LED 5 digit display
Degree of pollution 2
Operating altitude 2,000 m 6561 ft or less
Environmental resistance : Protection IP67
Environmental resistance : Ambient temperature -10 to +45 ℃ +14 to +113 ℉ (No dew condensation allowed), Storage: -20 to +60 ℃ -4 to +140 ℉
Environmental resistance : Ambient humidity 35 to 85 % RH, Storage: 35 to 85 % RH
Environmental resistance : Ambient illuminance Incandescent light: 3,000 liter x or less at the light-receiving face
(Note) The fluctuation by ambient illuminance is ± 0.1 % F.S. or less.
Insulation resistance 20 MOhm , or more, with 250 V DC between all supply teminals connected together and enclosure
Voltage withstandability 1,000 V AC for one min. between all supply terminals connected together and enclosure
Environmental resistance : Vibration resistance 10 to 55 Hz (period: 1 min.) frequency, 1.5 mm 0.059 in double amplitude in X,Y and Z directions for two hours each
Environmental resistance : Shock resistance 500 m/s2 acceleration (50 G approx.) in X,Y and Z directions three times each
Material Enclosure: PBT
Front cover: Acrylic
Cable: PVC
Cable 0.1mm2 10-core cabtyre cable, 5 m 16.404 ft long
Weight Net weight: 70 g approx. (not including cable), 320 g approx. (including cable)
Gross weight: 380 g approx.
Accessory Warning label: 1 set
Remark Where measurement conditions have not been specified precisely, the conditions used were as follows: supply voltage 24 V DC, ambient temperature +20 ℃ +68 ℉, sampling rate 500 μs, average number of samples: 1024, measurement center distance, object measured is made of white ceramic and analog measurement values.

Pliki do pobrania