Waga produktu: 30g
Minimalna ilość w zamówieniu: 1
Ilość produktów w opakowaniu jednostkowym: 1
Czujnik pomiarowy laserowy typu bariera. Seria HG-T
Item | Specifications |
---|---|
Product Number | HG-T1010 |
Part Number | HG-T1010 |
Regulatory compliance | CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations), FDA regulations |
Applicable controller | HG-TC101 (-P), HG-TC111 (-P), HG-TC113 |
Position detection method | CMOS-based |
Installation distance | 0 to 500 mm 0 to 19.685 in |
Measurement width | 10 mm 0.394 in |
Light source | Red semiconductor laser: Class 1 [IEC / JIS / GB / FDA (Note)] Maximum output: 0.3 mW, Peak emission wavelength: 655 nm (Note)This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 50, dated June 24, 2007, issued by CDRH (Center for Devices and Radiological Health) under the FDA (Food and Drug Administration). |
Repeatability | 1 μm 0.039 mil (Installation distance: 20 mm 0.787 in) 2.5 μm 0.098 mil (Installation distance: 100 mm 3.937 in) 5 μm 0.197 mil (Installation distance: 500 mm 19.685 in) (Note)This is the P-P value of digital measurement value with half shading at the middle position of the installation distance. |
Linearity | ±0.12 % F.S. (Installation distance: 20 mm 0.787 in) ±0.28 % F.S. (Installation distance: 100 mm 3.937 in) (Note)Indicates an error with the ideal straight line of digital measured values. |
Min. sensing object | ø0.5 mm ø0.020 in (Installation distance: 500 mm 19.685 in) (Note)When the light is blocked at the center position of 500 mm 19.685 in installation distance. |
Temprerature characteristics | ±0.03 % F.S./℃ (Note)When the light is half-blocked at the center position of 100 mm 3.937 in installation distance. |
Operation indicator | Emitter : Laser radiation indicator (Green) Receiver : Beam axis adjustment indicator (Orange / Green), Judgment output indicator (Orange / Green) |
Pollution degree | 2 |
Operating altitude | 2,000 m 6,561.68 ft or less (Note)Do not use or store in an environment that has been pressurized to an air pressure higher than the atmospheric pressure at 0 m. |
Environmental resistance : Protection | IP67 (IEC) (Excluding connectors) |
Environmental resistance : Ambient temperature | -10 to +45 ℃ +14 to +113 ℉ (No dew condensation or icing allowed), Storage: -20 to +60 ℃ -4 to +140 ℉ |
Environmental resistance : Ambient humidity | 35 to 85 % RH, Storage: 35 to 85 % RH |
Environmental resistance : Ambient illuminance | Incandescent light: 5,000 ℓx or less at the light-receiving face (Note)When the sampling cycle of the controller is set to "standard sampling". |
Environmental resistance : Insulation resistance | 20 MΩ or higher, using 250 V DC megger (between all terminals and case) |
Environmental resistance : Vibration resistance | 10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each |
Environmental resistance : Shock resistance | 196 m/s2 acceleration in X, Y and Z directions three times each |
Grounding method | Capacitor grounding |
Material | Case: Die-cast aluminum, Light emitting and light receiving surfaces: Glass |
Cable | 0.2 m 0.656 ft 4-core shielded cable with round connectors |
Net weight | Emitter: 30 g approx., Receiver: 30 g approx. |