Waga produktu: 80g
Minimalna ilość w zamówieniu: 1
Ilość produktów w opakowaniu jednostkowym: 1
Wąski dotykowy czujnik pomiarowy serii HG-S
Contact-Type Digital Displacement Sensor
Item | Specifications |
---|---|
Product Number | HG-S1110-AC |
Part Number | HG-S1110-AC |
Regulatory compliance | CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations) |
Applicable controller | HG-SC101(-P), HG-SC111(-P), HG-SC112(-P), HG-SC113 (Note) : Be sure to use the sensor in combination with an HG-SC□ controller manufactured in or after February 2019. |
Position detection method | Optical absolute linear encoder method |
Measuring range | 10 mm 0.394 in (Note) : The position that represents "0" as an absolute value is a position where the spindle is pushed further down from the bottom dead point by 0.1 mm 0.004 in or more. The term "stroke" indicates the total stroke length from the bottom dead point to the top dead point. |
Stroke | 10.5 mm 0.413 in or more (Note) : The position that represents "0" as an absolute value is a position where the spindle is pushed further down from the bottom dead point by 0.1 mm 0.004 in or more. The term "stroke" indicates the total stroke length from the bottom dead point to the top dead point. |
Measuring force | ・Measuring force changes with the air pressure used. Removing the seal cap enables the product to be used as the low measuring force type. ・For the relationship between supplied air pressure and measuring force or between measuring force and pushed spindle position, see the figures below. For upward mount without a seal cap, subtract 0.2 N from the measuring force. For side mount, subtract 0.1 N from the measuring force. The following figures are only typical examples, and these relationships differ depending on the assembly accuracy of the product or the abrasion status of sealing materials. |
Resolution | 0.1 μm 0.004 mil |
Sampling rate | 1 ms |
Indication accuracy(P-P) | Full range: 1.0 μm 0.039 mil or less Limited range: 0.5 μm 0.02 mil or less (any 60 μm 2.362 mil) |
Tip deviation amount | 35 μm 1.378 mil (typical value) |
Hot swap function | Incorporated |
Working pressure range | 0.14 to 0.16 MPa With no seal cap mounted : 0.035 to 0.045 MPa |
Capacity to resist pressure | 0.2 MPa |
Usable fluid | Clean air (Dew point temperature: -10 ℃ +14 ℉ or less) |
Applicable tube | Outside diameter: ø4 mm ø0.157 in / Inside diameter: ø2.5 mm ø0.098 in |
Operation indicator | Equipped (2-color LED: Orange / Green) |
Pollution degree | 2 |
Operating altitude | 2,000 m 6561.68 ft or less (Note) : Do not use or store in an environment that has been pressurized to an air pressure higher than the atmospheric pressure at 0 m. |
Environmental resistance : Protection | IP67 (IEC) With no seal cap mounted : - (Note) : Protective structure is not applicable when the sealing portions have deteriorated or become damaged. The protection level is zero when the seal cap is removed. |
Environmental resistance : Ambient temperature | -10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed), Storage: -20 to +60 ℃ -4 to +140 ℉ |
Environmental resistance : Ambient humidity | 35 to 85 % RH, Storage: 35 to 85 % RH |
Insulation resistance | 100 MΩ or more at 250 V DC |
Environmental resistance : Vibration resistance | 10 to 500 Hz frequency, 3 mm 0.118 in double amplitude (10 to 58 Hz), maximum acceleration 196 m/s2, (58 to 150 Hz) in X, Y, and Z directions for two hours each |
Environmental resistance : Shock resistance | 1,960 m/s2 acceleration in X, Y, and Z directions three times each |
Grounding method | Capacitor grounding |
Material | Body: Zinc, Holder: Stainless steel, Spindle: Tool steel, Probe (Note): Brass (body) / Ceramic (ball),, Air tube clamp: S60CM (Note) : The probe is also available as an option. |
Weight | Net weight: 80 g approx. |
Accessory | Sensor head fastening wrench: 1 pc., Mounting nut: 1 pc., Seal cap: 1pc, Air tube clamp: 1 pc. |
Remark | Where measurement conditions are not specified, the conditions used were as follows: standard type measurement probe (HG-SS10C), ambient temperature of +20 ℃ +68 ℉, and a clean atmosphere where water, oil, other liquids or dust does not come in contact with the equipment. |