Waga produktu: 180g
Minimalna ilość w zamówieniu: 1
Ilość produktów w opakowaniu jednostkowym: 1
Wąski dotykowy czujnik pomiarowy serii HG-S
Contact-Type Digital Displacement Sensor
Item | Specifications |
---|---|
Product Number | HG-S1050 |
Part Number | HG-S1050 |
Regulatory compliance | CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations) |
Applicable controller | HG-SC101(-P), HG-SC111(-P), HG-SC112(-P), HG-SC113 (Note) : Always connect the 50 mm 1.969 in type (HG-S1050) to an HG-SC□ controller manufactured February 2019 or later. |
Position detection method | Optical absolute linear encoder method |
Measuring range | 50 mm 1.969 in |
Stroke | 50.5 mm 1.988 in or more |
Measuring force : Downward mount | 3.8 N or less (50 mm 1.969 in pressing position) 1.9 N (intermediate position) (Note) : Typical value near center of measurement. |
Measuring force : Upward mount | 3.2 N or less (50 mm 1.969 in pressing position) 1.4 N (intermediate position) (Note) : Typical value near center of measurement. |
Measuring force : Side mount | 3.4 N or less (50 mm 1.969 in pressing position) 1.7 N (intermediate position) (Note) : Typical value near center of measurement. |
Resolution | 0.5 μm 0.020 mil |
Sampling rate | 1 ms |
Indication accuracy(P-P) | Full range: 3.5 μm 0.138 mil or less |
Tip deviation amount | 40 μm 1.575 mil or less (typical) (Note) : Value calculated from the clearance of the upper and lower plain bearings. |
Hot swap function | Incorporated |
Operation indicator | 2-color LED (Orange / Green) |
Pollution degree | 2 |
Operating altitude | 2,000 m 6561.68 ft or less (Note) : Do not use or store in an environment that has been pressurized to an air pressure higher than the atmospheric pressure at 0 m. |
Environmental resistance : Protection | IP67 (IEC) (Note) : Excludes damage and deterioration to rubber bellows due to external causes. |
Environmental resistance : Ambient temperature | -10 to +55 ℃ +14 to +131 ℉ (No condensation or icing allowed), Storage: -20 to +60 ℃ -4 to +140 ℉ |
Environmental resistance : Ambient humidity | 35 to 85 % RH, Storage: 35 to 85 % RH |
Insulation resistance | 100 MΩ or more at 250 V DC |
Environmental resistance : Vibration resistance | 10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each |
Environmental resistance : Shock resistance | 980 m/s2 acceleration in X, Y and Z directions three times each |
Grounding method | Capacitor grounding |
Material | Body: Aluminum alloy, Holder: Free-cutting steel, Spindle: Carbon tool steel, Probe (Note): Brass (body) / Ceramic (ball), Rubber bellows: NBR (black) (Note) : The probes (optional) are also available. |
Weight | Main unit weight: 180 g approx. |
Accessory | Sensor head fastening wrench 1 pc., Mounting nut 1 pc. |
Remark | Where measurement conditions have not been specified precisely, the conditions used were as follows: standard type measurement probe (HG-SS10C), ambient temperature +20 ℃ +68 ℉, and a clean atmosphere where dust and liquids such as water and oil do not come in contact with the equipment. |