Oferta


Automatyka przemysłowa

Filtruj


Producent

Cena promocyjna

HGS1010AC


Typ: Czujniki pomiarowe

Symbol: HG-S1010-AC

Producent: Panasonic

Waga produktu: 80g

Minimalna ilość w zamówieniu: 1

Ilość produktów w opakowaniu jednostkowym: 1

Opis produktu


Wąski dotykowy czujnik pomiarowy serii HG-S

Contact-Type Digital Displacement Sensor

Item Specifications
Product Number HG-S1010-AC
Part Number HG-S1010-AC
Regulatory compliance CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations)
Applicable controller HG-SC101(-P), HG-SC111(-P), HG-SC112(-P), HG-SC113
(Note) : Be sure to use the sensor in combination with an HG-SC□ controller manufactured in or after February 2019.
Position detection method Optical absolute linear encoder method
Measuring range 10 mm 0.394 in
(Note) : The position that represents "0" as an absolute value is a position where the spindle is pushed further down from the bottom dead point by 0.1 mm 0.004 in or more. The term "stroke" indicates the total stroke length from the bottom dead point to the top dead point.
Stroke 10.5 mm 0.413 in or more
(Note) : The position that represents "0" as an absolute value is a position where the spindle is pushed further down from the bottom dead point by 0.1 mm 0.004 in or more. The term "stroke" indicates the total stroke length from the bottom dead point to the top dead point.
Measuring force ・Measuring force changes with the air pressure used. Removing the seal cap enables the product to be used as the low measuring force type.
・For the relationship between supplied air pressure and measuring force or between measuring force and pushed spindle position, see the figures below. For upward mount without a seal cap, subtract 0.2 N from the measuring force. For side mount, subtract 0.1 N from the measuring force. The following figures are only typical examples, and these relationships differ depending on the assembly accuracy of the product or the abrasion status of sealing materials.
the relationship between supplied air pressure and measuring force or between measuring force and pushed spindle position
Resolution 0.5 μm 0.02 mil
Sampling rate 1 ms
Indication accuracy(P-P) Full range: 2.0 μm 0.079 mil or less
Limited range: 1.0 μm 0.039 mil or less
(any 60 μm 2.362 mil)
Tip deviation amount 35 μm 1.378 mil (typical value)
Hot swap function Incorporated
Working pressure range 0.14 to 0.16 MPa
With no seal cap mounted : 0.035 to 0.045 MPa
Capacity to resist pressure 0.2 MPa
Usable fluid Clean air (Dew point temperature: -10 ℃ +14 ℉ or less)
Applicable tube Outside diameter: ø4 mm ø0.157 in / Inside diameter: ø2.5 mm ø0.098 in
Operation indicator Equipped (2-color LED: Orange / Green)
Pollution degree 2
Operating altitude 2,000 m 6561.68 ft or less
(Note) : Do not use or store in an environment that has been pressurized to an air pressure higher than the atmospheric pressure at 0 m.
Environmental resistance : Protection IP67 (IEC)
With no seal cap mounted : -
(Note) : Protective structure is not applicable when the sealing portions have deteriorated or become damaged. The protection level is zero when the seal cap is removed.
Environmental resistance : Ambient temperature -10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed),
Storage: -20 to +60 ℃ -4 to +140 ℉
Environmental resistance : Ambient humidity 35 to 85 % RH, Storage: 35 to 85 % RH
Insulation resistance 100 MΩ or more at 250 V DC
Environmental resistance : Vibration resistance 10 to 500 Hz frequency, 3 mm 0.118 in double amplitude (10 to 58 Hz), maximum acceleration 196 m/s2, (58 to 150 Hz) in X, Y, and Z directions for two hours each
Environmental resistance : Shock resistance 1,960 m/s2 acceleration in X, Y, and Z directions three times each
Grounding method Capacitor grounding
Material Body: Zinc, Holder: Stainless steel, Spindle: Tool steel, Probe (Note): Brass (body) / Ceramic (ball),, Air tube clamp: S60CM
(Note) : The probe is also available as an option.
Weight Net weight: 80 g approx.
Accessory Sensor head fastening wrench: 1 pc., Mounting nut: 1 pc., Seal cap: 1pc, Air tube clamp: 1 pc.
Remark Where measurement conditions are not specified, the conditions used were as follows: standard type measurement probe (HG-SS10C), ambient temperature of +20 ℃ +68 ℉, and a clean atmosphere where water, oil, other liquids or dust does not come in contact with the equipment.

Mimo dołożenia wszelkich starań nie gwarantujemy, że publikowane dane techniczne oraz zdjęcia nie zawierają braków lub błędów. Ponieważ ewentualne błędy nie mogą być podstawą do roszczeń, w przypadku wątpliwości prosimy przed zakupem o kontakt z handlowcem.