Waga produktu: 85g
Minimalna ilość w zamówieniu: 1
Ilość produktów w opakowaniu jednostkowym: 1
Czujnik pomiarowy serii HG-C
Item | Specifications |
---|---|
Product Number | HG-C1200-P |
Part Number | HG-C1200-P |
Applicable regulations and certifications | CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations), FDA Regulations, UL/c-UL Certification (Note) : The UL/c-UL certified products have been shipped since April, 2017. |
Measurement center distance | 200 mm 7.874 in |
Measuring range | ±80 mm 3.150 in |
Repeatability | 200 μm 7.874 mil |
Linearity | ±0.2%F.S. |
Temprerature characteristics | 0.03% F.S./℃ |
Light source | Red semiconductor laser Class 2 [JIS/IEC/GB/FDA (Note) ] Max. output: 1 mW emission peak wavelength: 655 nm 0.026 mil (Note) This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 50, dated June 24, 2007, issued by CDRH (Center for Devices and Radiological Health) under the FDA (Food and Drug Administration). |
Beam diameter | ø300 μm 11.8111 mil approx. (Note) This is the size in the measurement center distance. These values were defined by using 1/e2 (13.5% approx.) of the center light intensity. Due to leak light outside the specified area, the reflectance around the detecting point may be higher than at the point and this may affect the measurement value. |
Supply voltage | 12 to 24 V DC ±10 %, Ripple P-P 10 % or less |
Current consumption | 40 mA or less (at 24V DC supply voltage) 65 mA or less (at 12V DC supply voltage) Note : Specifications have been changed from shipment in August, 2016. For shipment before July 2016 : 40 mA or less (at 24 V DC supply voltage), 60 mA or less (at 12 V DC supply voltage) |
Control output | PNP open-collector transistor - Maximum source current: 50 mA - Applied voltage: 30 V DC or less (Between control output to +V) - Residual voltage: 1.5 V or less (At 50 mA source current) - Leakage current: 0.1 mA or less |
Control output:Output operation | Either Light-ON or Dark-ON |
Control output:Short-circuit protection | Incorporated (Auto reset type) |
Analogue output : Analog voltage output | • Output range: 0 to 5 V (at alarm: +5.2 V) • Output impedance: 100Ω |
Analogue output : Analog current output | • Output range: 4 to 20mA (at alarm: 0mA) • Output impedance: 300Ω or less Note : Analog current output has been added from shipment in August 2016. |
Response time | Switchable between 1.5 ms / 5 ms / 10 ms |
External input | PNP non-contact input - Input conditions Invalid: 0 to +0.6 V DC or Open Valid: +4 to +V DC - Input impedance: 10 kΩ approx. |
Pollution degree | 2 |
Operating altitude | 2,000 m 6561.680 ft or less |
Protection | IP67 (IEC) |
Ambient temperature | -10 to +45 ℃ -14 to 113 ℉ (No dew condensation or icing allowed), Storage: -20 to +60 ℃ -4 to 140 ℉ |
Ambient humidity | 35 to 85 % RH, Storage: 35 to 85 % RH |
Ambient illuminance | Incandescent light: 3,000 ℓx or less at the light-receiving face |
Vibration resistance | 10 to 55 Hz (period: 1 min.) frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each |
Shock resistance | 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each |
Cable | 5-core composite cable, 2 m 6.5617 ft long |
Cable extension | Extension up to total 10 m 393.701 ft is possible with 0.3 mm2, or more, cable. |
Material | Enclosure: Aluminum die-cast Front cover: Acrylic |
Weight | Net weight: 35 g approx. (without cable), 85 g approx. (including cable) |