Waga produktu: 200g
Minimalna ilość w zamówieniu: 1
Ilość produktów w opakowaniu jednostkowym: 1
High Speed・High Accuracy Eddy Current Type Digital Displacement Sensor GP-X
Threaded type sensor head + Controller
Eddy current, 22 mm diameter, PNP
Item | Specifications |
---|---|
Product Number | GP-XC22KL-P |
Part Number | GP-XC22KL-P |
Item | Specifications |
---|---|
Type | PNP output |
Supply voltage | 24 V DC plus or minus 10 % Ripple P-P 10 % or less |
Current consumption | 150 mA or less |
Resolution | 0.02 % F.S. (64 times average processing) (Note) This value was obtained at a constant +25 ℃ +77 ℉ . |
Sampling frequency | 40 kHz (25 micro s) |
Linearity | Within plus or minus 0.3 % F.S. (Note) This value was obtained at a constant +25 ℃ +77 ℉ . |
Temperature characteristics | 0.07 % F.S./℃ or less (Note) This value represents 20 to 60 % of the maximum sensing distance when combining the sensor head and controller. |
Analog voltage outputs | Output voltage: -5 to +5 V (Note1) , Output impedance: 100 Ω approx.(Note2) (Note1: Adjusted to a 0 to +5 V factory setting.) (Note2:When using the BCD output unit GP-XBCD, the analog voltage output of a controller becomes invalid.) |
Analog voltage outputs : Response time | 75 micro s (maximum speed) |
Comparative outputs (HI, GO, LO) | PNP open-collector transistor -Maximum source current: 100 mA -Applied voltage: 30 V DC or less (between comparative output and +V) -Residual voltage: 1.6 V or less (at 100 mA source current), 0.4 V or less (at 16 mA source current) |
Comparative outputs (HI, GO, LO) : Utilization category | DC-12 or DC-13 |
Comparative outputs (HI, GO, LO) : Output number | HI / GO / LO 3 value output |
Comparative outputs (HI, GO, LO) : Output operation | HI: ON when measured value > the upper limit value GO: ON when upper limit value >= measured value >= lower limit value LO: ON when lower limit value > measured value |
Comparative outputs (HI, GO, LO) : Short-circuit protection | Incorporated |
External input | Photo-coupler input - Input current: 9 mA or less - Operating voltage: ON voltage 17 V or more (between 0 V and input), OFF voltage 4 V or less (between 0 V and input) - Input impedance: 5 kΩ approx. |
Serial I/O | RS-232C |
Zero-set setting method | Push button setting / External input setting |
Indicators : MODE | Orange LED (lights up when in mode status) |
Indicators : HI | Orange LED (lights up when the upper limit value is exceeded) |
Indicators : GO | Green LED (lights up when within the upper and lower limit value) |
Indicators : LO | Orange LED (lights up when less than the lower limit value) |
Indicators : TIMING | Green LED (lights up as per the external or internal trigger timing) |
Upper level digital display part | 5 digit orange LED (display of numerical values out of upper and lower limit value) |
Lower level digital display part | 5 digit green LED (display of numerical values within the upper and lower limit value) |
Pollution degree | 3 (Industrial environment) |
Ambient temperature | 0 to +50 ℃ +32 to +122 ℉ (No dew condensation allowed), Storage: 0 to +50 ℃ +32 to +122 ℉ |
Ambient humidity | 35 to 85 % RH, Storage: 35 to 85 % RH |
Vibration resistance | 10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each |
Shock resistance | 100 m/s2 acceleration (10 G approx.) in X, Y and Z directions five times each |
Material | Enclosure: Polycarbonate |
Weight | Net weight: 120 g approx. |
Accessory | ATA4811 (Controller mounting frame): 1 set |
Item | Specifications |
---|---|
Type | Threaded type For 10 mm 0.394 in sensing |
Sensing range | 0 to 10 mm 0 to 0.394 in (Note) The sensing range is specified for the standard sensing object. |
Standard sensing object | Stainless steel (SUS304) / Iron sheet [Cold rolled carbon steel (SPCC)] 60 x 60 x t 1 mm 2.362 x 2.362 x t 0.039 in |
Temperature characteristics | 0.07 % F.S./℃ or less (Note) This value represents 20 to 60 % of the maximum sensing distance when combining the sensor head and the controller. |
Pollution degree | 3 (Industrial environment) |
Protection | IP67 (IEC), IP67g (Note:If using the sensor in an environment where cutting oil droplets splatter, the sensor may be deteriorated due to added substances in the oil. Please check the resistivity of the sensor against the cutting oil you are using beforehand.) |
Ambient temperature | -10 to +55 ℃ +14 to +131 ℉ , Storage: -20 to +70 ℃ -4 to +158 ℉ |
Ambient humidity | 35 to 85 % RH, Storage: 35 to 85 % RH |
Voltage withstandability | 250 V AC for one min. between all supply terminals connected together and enclosure |
Insulation resistance | 20 MΩ , or more, with 250 V DC megger between all supply terminals connected together and enclosure |
Vibration resistance | 10 to 150 Hz frequency, 0.75 mm 0.030 in amplitude in X, Y and Z directions for two hours each |
Shock resistance | 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions five times each |
Enclosure | Brass (Nickel plated) |
Cable protector | PP |
Sensing part | PA |
Cable | High frequency coaxial cable with connector, 3 m 9.843 ft long (Note) For the flexible cable type, please contact our office. |
Cable extension | Extension up to total 10 m 32.808 ft is possible with the optional cable. |
Net Weight | 80 g approx. (Note) The given weight of the threaded type sensor head is the value including the weight of the nuts and the toothed lock washer. |
Accessories | Nut: 2 pcs. Toothed lock washer: 1 pc. |