Waga produktu: 25g
Minimalna ilość w zamówieniu: 1
Ilość produktów w opakowaniu jednostkowym: 1
Expansion lens |
FX-LE1 | ![]() |
Increases the sensing range by 5 times or more. ・ Ambient temperature: -60 to +350 ℃ -76 to +662 ℉ (Note 2) ・ Beam dia: ø3.6 mm ø0.142 in Sensing range (mm in) [Lens on both sides] |
---|
FX-LE1 Sensing range (mm) [Lens on both sides]
Amplifiers | FX-500 series (Upper value) FX-550 / FX-550L series (Lower value) |
FX-100 series | ||||||
---|---|---|---|---|---|---|---|---|
Mode | HYPR | U-LG | LONG | STD | FAST | H-SP | FX-101 | FX-102 |
FT-43 | 3,600 (Note 1) 3,600 (Note 1) |
3,600 (Note 1) 3,600 (Note 1) |
3,600 (Note 1) 3,600 (Note 1) |
3,600 (Note 1) 3,600 (Note 1) |
3,600 (Note 1) 3,600 (Note 1) |
1,600 - |
2,400 | 3,600 (Note 1) |
FT-42 FT-42W |
3,600 (Note 1) 3,600 (Note 1) |
3,600 (Note 1) 3,600 (Note 1) |
3,600 (Note 1) 3,600 (Note 1) |
3,600 (Note 1) 3,600 (Note 1) |
3,600 (Note 1) 3,600 (Note 1) |
2,200 - |
3,400 | 3,600 (Note 1) |
FT-45X | 1,600 (Note 1) 1,600 (Note 1) |
1,600 (Note 1) 1,600 (Note 1) |
1,600 (Note 1) 1,600 (Note 1) |
1,600 (Note 1) 1,600 (Note 1) |
1,600 (Note 1) 1,600 (Note 1) |
1,500 - |
1,600 (Note 1) |
1,600 (Note 1) |
FT-R40 | 3,600 (Note 1) 3,600 (Note 1) |
3,600 (Note 1) 3,600 (Note 1) |
3,600 (Note 1) 3,600 (Note 1) |
3,600 (Note 1) 3,600 (Note 1) |
3,600 (Note 1) 3,600 (Note 1) |
1,900 - |
3,100 | 3,600 (Note 1) |
FT-R43 FT-R44Y |
3,600 (Note 1) 3,600 (Note 1) |
3,600 (Note 1) 3,600 (Note 1) |
3,600 (Note 1) 3,600 (Note 1) |
3,600 (Note 1) 3,600 (Note 1) |
1,900 1,600 (Note 1) |
670 - |
1,300 | 3,600 (Note 1) |
FT-H35-M2 | 3,600 (Note 1) 3,600 (Note 1) |
3,600 (Note 1) 3,600 (Note 1) |
3,600 (Note 1) 3,600 (Note 1) |
3,600 (Note 1) 3,600 (Note 1) |
3,300 3,600 (Note 1) |
1,400 - |
2,000 | 3,500 (Note 1) |
FT-H20W-M1 | 1,600 (Note 1) 1,600 (Note 1) |
1,600 (Note 1) 1,600 (Note 1) |
1,600 (Note 1) 1,600 (Note 1) |
1,600 (Note 1) 1,600 (Note 1) |
1,600 (Note 1) 1,600 (Note 1) |
850 - |
1,300 | 1,600 (Note 1) |
FT-H20-M1 | 1,600 (Note 1) 1,600 (Note 1) |
1,600 (Note 1) 1,600 (Note 1) |
1,600 (Note 1) 1,600 (Note 1) |
1,600 (Note 1) 1,600 (Note 1) |
1,600 (Note 1) 1,600 (Note 1) |
1,200 - |
1,600 (Note 1) |
1,600 (Note 1) |
FT-H20-J50-S FT-H20-J30-S FT-H20-J20-S |
3,600 (Note 1) 3,600 (Note 1) |
3,600 (Note 1) 3,600 (Note 1) |
3,500 3,600 (Note 1) |
2,000 3,600 (Note 1) |
1,600 3,600 (Note 1) |
500 - |
1,000 | 3,500 (Note 1) |
(Note 1): | The fiber cable length practically limits the sensing range. |
---|