Waga produktu: 220g
Minimalna ilość w zamówieniu: 1
Ilość produktów w opakowaniu jednostkowym: 1
Part Number | AFP7CPS3RES |
Product | FP7 CPU units |
Details | Security enhanced type |
Product name | FP7 |
Item | Specifications |
---|---|
Memory capacity:Memory selection pattern1 | Program (steps): 121,500 Data register (Note 1): 131,072 Number of max. program block (PB): 243 (Note) The factory default setting is pattern 1. (Note 1) For data register (DT), data up to 262,144 words can be backed up. |
Memory capacity:Memory selection pattern2 | Program (steps): 96,000 Data register (Note) : 262,144 Number of max. program block (PB): 192 (Note) For data register (DT), data up to 262,144 words can be backed up. |
Memory capacity:Memory selection pattern3 | Program (steps): 64,000 Data register (Note) : 425,984 Number of max. program block (PB): 128 (Note) For data register (DT), data up to 262,144 words can be backed up. |
Memory capacity:Memory selection pattern4 | Program (steps): 32,000 Data register (Note) : 589,824 Number of max. program block (PB): 64 (Note) For data register (DT), data up to 262,144 words can be backed up. |
Programming method | Relay symbol method |
Control method | Cyclic operation method |
Program memory | Built-in flash ROM (no backup battery required) |
Operation speed | Basic instruction: min. 11 ns/step |
External input (X) | 8,192 points (Note) Hardware configuration governs the actually usable number of I/O points. When I/O points are not actually used, usable as internal relays. |
External output (Y) | 8,192 points (Note) Hardware configuration governs the actually usable number of I/O points. When I/O points are not actually used, usable as internal relays. |
Internal relay (R) | 32,768 points |
System relay (SR) | Indicate operation status of various relays is shown. |
Link relay (L) | 16,384 points |
Timer (T) | 4,096 points: Timer capable of counting (units: 10 micro s, 1 ms, 10 ms, 100 ms or 1 sec.) x 4,294,967,295 |
Counter (C) | 1,024 points, Counter capable of counting 1 to 4,294,967,295 |
Link data register (LD) | 16,384 words |
System data register (SD) | Internal operation status of various registers is shown. |
Index register (I0 to IE) | 15 long words / With switching function |
Master control relay (MCR) | Unlimited |
Number of labels (LOOP) | Max. 65,535 points for each program block (PB) |
Differential points | Unlimited |
Number of step ladders | Unlimited |
Number of subroutines | Max. 65,535 points for each program block (PB) |
Number of interrupt program | 1 periodical interrupt program |
SD memory card function | SDHC memory cards of up to 32 GB are usable. |
Constant scan | Available (0 to 125 ms) |
Clock / calendar | Year (last two digits), month, day, hours (24-hour display) minutes, seconds, day of week (Note)Precision of calendar; At 0 ℃ +32 ℉, 95 sec. or less error per month, at +25 ℃ +77 ℉, 15 sec. or less error per month, at +55 ℃ +131 ℉, 130 sec. or less error per month |
Battery life (Value applies when no power is supplied at all.) | 3.3 years or more (when no power is supplied) actual usage value: 20 years approx. (at 25 degrees 77 degrees Fahrenheit ) |
Safety function | Password / Restricted distribution / Read disable setting / Encryption |
PLC link function (Serial communication / MEWNET-W0) |
Max. 16 units, link relays: 1,024 points, link registers: 128 words. (Data transfer and remote programming are not supported) (Link area allocation is switchable between the first and the second half) |
Item | Specifications |
---|---|
Interface | RS-232C, three-wire system, 1 channel (Note) SD, RD and SG terminals are isolated from internal circuits. |
Transmission distance | 15 m 49.213 ft |
Transmission speed | 300, 600, 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200, 230400 bits/sec, |
Communication method | Half-duplex system |
Synchronous method | Start-stop synchronization system |
Transmission format | Stop bit: 1 bit / 2 bits Parity: none / odd / even Data length: 7 bits / 8 bits Start code: with STX / without STX End code: CR / CR + LF / none / ETX |
Data transmission order | Transmit from bit 0 in character units. |
Connection | General-purpose communication, Computer link and MODBUS-RTU |
Item | Specifications |
---|---|
Terminal:5V | For 5 V DC type GT series Programmable Display (Note) 5 V and 24 V DC types are not usable at the same time. |
Terminal:24V | For 24 V DC type GT series Programmable Display (Note 1) 5 V and 24 V DC types are not usable at the same time. (Note 2) Use 21.6 to 26.4 V DC to power the CPU unit. Please check the “GT Series Hardware Manual” for grounding of the GT series programmable display. |
Item | Specifications |
---|---|
Communication interface | Ethernet 100BASE-TX / 10BASE-TX |
Communication speed | 100 Mbps, 10 Mbps auto negotiation function |
Total cable length | 100 m 328 ft (500 m 1,640 ft when a repeater is used) |
Number of nodes | Max. 254 units |
Number of simultaneous connections | Max. 220 connections (user connection: 216, system connection: 4) |
Communication protocol (Communication layer) | TCP / IP, UDP |
DNS | Supports name servers |
DHCP / DHCPV6 | Automatic IP address acquisition |
FTP server / Client (SSL compatible) | Server function, file transfer, number of user: 3 Client function, data and file transfer |
HTTP server / Client (SSL compatible) | Server function, system web, Customer web (8 MB), number of concurrent session: 16 Client function, data transfer |
SMTP client (SSL compatible) | Client function, mail transfer |
SNTP | Time adjustment function |
General-purpose communication | 16 kB / 1 connection (user connection: 1 to 16) |
Dedicated communication | Slave communication (MEWTOCOL-COM, MEWTOCOL7-COM, MEWTOCOL-DAT, MODBUS-TCP, MC protocol (Note)) Master communication (MEWTOCOL-COM, MEWTOCOL-DAT, MODBUS-TCP, MC protocol (Note)) (Note): MC protocol is a short form denoting MELSEC communication protocol; MELSEC is a registered trademark of Mitsubishi Electric Corporation. QnA compatible 3E frame, only binary (bulk writing and bulk reading) use is available. |
Item | Specifications |
---|---|
Ambient temperature | 0 to +55 ℃ +32 to +131 ℉, Storage: -40 to +70 ℃ -40 to +158 ℉ |
Ambient humidity | 10 to 95 % RH (at +25 ℃ +77 ℉, no condensation), Storage: 10 to 95 % RH (at +25 ℃ +77 ℉, no condensation) |
Vibration resistance | 5 to 8.4 Hz, single amplitude of 3.5 mm 0.138 in, 1 sweep/min. (IEC 61131-2) ; 8.4 to 150 Hz, constant acceleration of 9.8 m/s2, 1 sweep/min. (IEC 61131-2), 10 times each in X, Y, and Z directions |
Shock resistance | 147 m/s2 or more , 3 times each in X, Y, and Z directions (IEC61131-2) |
Noise immunity | 1,000 V [p-p] with pulse width 50 ns and 1 micro s (using a noise simulator) |
Operating condition | Free from corrosive gasses and excessive dust |
Item | Specifications |
---|---|
Rated voltage range | 20.4 to 28.8 V DC |
Current consumption | 200 mA or less |
Net weight | 220 g approx. (with terminal block and end unit) |