Waga produktu: 80g
Minimalna ilość w zamówieniu: 1
Ilość produktów w opakowaniu jednostkowym: 1
Part Number | AFP0HPG02L |
Product name | FP0H positioning units |
Item | Specifications |
---|---|
Product Number | AFP0HPG02L |
Part Number | AFP0HPG02L |
Output type | Line driver |
Number of occupied points | Input 32 points, Output 32 points |
Number of axes controlled | 2 axes, independent |
Position command : Command units | Pulse unit (The program specifies whether Increment or Absolute is used.) |
Position command : Max. pulse count | Signed 32 bits (-2,147,483,648 to +2,147,483,647 pulses) |
Speed command : Command range | 1 pps to 4 Mpps(can set in 1 pps.) |
Acceleration / deceleration command : Acceleration / deceleration method | Linear acceleration / deceleration, S acceleration / deceleration |
Acceleration / deceleration command : S-curve type | Can select from Sin curve, Secondary curve, Cycloid curve and Third curve. |
Acceleration / deceleration command : Acceleration / deceleration time | 0 to 32,767 ms (can set in 1 ms) |
Home return : Home return speed | Speed setting possible (changes return speed and search speed) |
Home return : Input signal | Home input, Near home input, Over limit input (+), Over limit input (-) |
Home return : Output signal | Deviation counter clear signal |
Operation mode | E point control (Linear accelerations / decelerations, S accelerations / decelerations) P point control (Linear accelerations / decelerations, S accelerations / decelerations) Home return function (Home search) JOG operation function (Note 1) JOG positioning function Pulser input function (Note 2) • Transfer multiplication ratio (× 1, × 2, × 5, × 10, × 50, × 100, × 500, × 1000) Real-time frequency change function Infinity output function Note1 : When selected linear acceleration / deceleration operation, the target speed can be changed during an operation. Note2 : Pulser input function and feedback counter function use the same pulse input terminal, so the both cannot function simultaneously. |
Startup time | 0.02 ms or 0.005 ms selectable (Note) Note : The startup time can be changed by the control code setting in the shared memory. The factory setting (default setting) is 0.02 ms. The startup time is the time from the start request to the first pulse output. |
Output interface : Output mode | 1 pulse output (Pulse and Sign), 2-pulse output (CW and CCW) |
Feed back counter function : Countable range | Signed 32 bits (-2,147,483,648 to +2,147,483,647 pulses) Note : Pulser input function and feedback counter function use the same pulse input terminal, so the both cannot function simultaneously. |
Feed back counter function : Input mode | Two-phase input, Direction distinction input, Individual input (transfer multiple available for each.) Note : Pulser input function and feedback counter function use the same pulse input terminal, so the both cannot function simultaneously. |
Other functions | The flag to compare the elapsed value is built in. (The timing signal outputs at the optional position during an operation.) |
External power supply : Voltage | 21.6 to 26.4 V DC |
External power supply : Current consumption | 30 mA |
Net weight | 80 g approx. |